Florida SWPPP
Everything You Need to Know About Your SWPPP
Requirements for Construction in Florida
What is a SWPPP?
A SWPPP stands for Storm Water Pollution Prevention Plan
Why Do I Have to Have One?
In Florida, the Department of Environmental Protection (DEP) requires a SWPPP to comply with both the Environmental Protection Agency (EPA) guidelines and state-specific regulations under the Florida Construction General Permit for stormwater discharges associated with industrial activity. This is to ensure the protection of Florida’s water resources during construction activities.
What happens if I don’t do my SWPPP and just let it ride in Florida?
In Florida, the Department of Environmental Protection (DEP) closely monitors construction activities to ensure they comply with state regulations aimed at minimizing stormwater pollution. For construction projects that disturb one acre or more of land, obtaining coverage under the National Pollutant Discharge Elimination System (NPDES) stormwater permit is mandatory. This is in alignment with federal EPA guidelines, but with Florida’s specific conditions and requirements integrated into the process.
Failing to comply with Florida’s NPDES permit requirements for stormwater discharges can lead to severe consequences. If a construction project is found to be in violation of its NPDES permit requirements, the DEP can issue stop-work orders, effectively halting construction activities until compliance is achieved. This can delay your project significantly, leading to increased costs and potential legal fees. Furthermore, the DEP can impose fines that vary depending on the severity and duration of the violation. These fines are not just punitive but are also meant to cover the cost of any environmental damage and deter future non-compliance.
I have an Erosion Control Plan drawing in my Civil’s… Isn’t that my SWPPP?
It’s a common misconception that an Erosion Control Plan or a Best Management Practices (BMP) plan included in your civil engineering packet is the same as your SWPPP. While these documents are crucial components of your overall stormwater management strategy, they do not constitute a complete SWPPP. In Florida, a comprehensive SWPPP includes far more than just erosion and sediment control measures.
Your SWPPP should be a detailed document—often spanning over a hundred pages—that consists of all aspects of your project’s potential impact on stormwater quality. This includes a Notice of Intent (NOI) if required, a Notice of Termination (NOT) upon project completion, any necessary modifications to the plan, and specific construction site notices. Additionally, a robust SWPPP includes logs for daily activities, employee training, and regular inspections, ensuring that all measures are effectively implemented and maintained throughout the project’s duration.
A fully developed SWPPP is a dynamic document that evolves with your project, professionally crafted to address all potential stormwater disturbances. By comprehensively planning and documenting your stormwater management efforts, you not only comply with Florida’s regulations but also play an active role in preserving the state’s precious water resources.
How am I going to install my Silt Fence and Inlet Protection?
At Pro SWPPP, we make it straightforward for you to manage all stormwater requirements for your construction site in Florida. Your SWPPP will likely include detailed instructions for installing Silt Fences, Inlet Protection, and a Stabilized Construction Entrance, essential components for effective erosion and sediment control. While we recommend managing these installations yourself due to the simplicity of the process, hiring a local contractor familiar with Florida’s environmental regulations can also be a good move. For those who prefer a hands-on approach, we can guide you towards trusted wholesale providers for all necessary materials, ensuring you’re equipped to implement the Best Management Practices (BMPs) outlined in your SWPPP.
Can I at least do my own SWPPP Inspections?
Definitely. Pro SWPPP empowers you to take charge of your own SWPPP compliance by providing a Letter of Delegation. This document authorizes your Site Foreman or another designated individual to conduct weekly SWPPP Site Inspections. To streamline the process, we include a comprehensive Inspection Form in your SWPPP package. Alternatively, you can choose to use our Online Inspections Portal, allowing for convenient inspections via a mobile device with all data securely stored in the cloud.
Ultimately, whether you need a Construction SWPPP or an Industrial SWPPP in Florida, clicking the ‘Get My SWPPP’ button connects you with Pro SWPPP’s expertise. We’re dedicated to providing top-tier service and reliability, ensuring your project adheres to Florida’s specific environmental protection standards with ease.
.
Why wait? Why pay more? Why take a risk?
You will have it in 72 hours, or it’s free.
We have a perfect, 100% compliance record.
If you have any questions before you order, please call Derek at: 833-GET-SWPP.